Оборудование оснащено функцией самодиагностики. При обнаружении проблемы, аппарат блокируется, на дисплее отображается код вида С#### с указанием характера проблемы. Также появляется сообщение необходимости обслуживания. После устранения проблемы, ошибку можно сбросить тумблером питания, выключив и включив аппарат.
Код |
Значение |
Описание |
Причина |
Решение |
C0030 |
FAX control PWB system error |
Processing with the fax software was disabled due to a hardware problem. |
Defective FAX control PWB. |
Replace the FAX control PWB. |
C0070 |
FAX control PWB incompatible detection Error |
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. |
Defective fax software. |
Install the fax software. |
Defective FAX control PWB. |
Replace the FAX control PWB. |
|||
C0100 |
Backup memory device error |
Defective flash memory. |
Replace the control PWB. |
|
Defective control PWB. |
Replace the control PWB. |
|||
C0120 |
MAC address data error |
Defective flash memory. |
Replace the control PWB. |
|
C0130 |
Backup memory read/write error |
Defective flash memory. |
Replace the control PWB. |
|
Defective control PWB. |
Replace the control PWB. |
|||
C0140 |
Backup memory data error |
Defective flash memory. |
Replace the control PWB. |
|
Defective control PWB. |
Replace the control PWB. |
|||
C0150 |
Control PWB EEPROM error |
Detecting control PWB EEPROM (U17) communication error. |
Improper installation control PWB EEPROM (U17). |
Check the installation of the EEPROM (U17) and remedy if necessary. |
Defective control PWB. |
Replace the control PWB. |
|||
Data damage of control PWB EEPROM (U17). |
Contact the Service Administrative Division. |
|||
C0170 |
Billing counting error |
Defective control PWB. |
Replace the control PWB. |
|
Data damage of control PWB EEPROM (U17). |
Contact the Service Administrative Division. |
|||
C0180 |
Machine number mismatch |
Machine number of main and engine does not match. |
The main PWB or the engine PWB were exchanged. |
U004 Setting the machine number. |
Data damage of control PWB EEPROM (U17). |
Contact the Service Administrative Division. |
|||
C0420 |
Paper feeder communication error |
Communication error between control PWB and optional paper feeder. |
Improper installation paper feeder. |
Follow installation instruction carefully again. |
Defective harness between control PWB (YC30) and paper feeder interface connector, or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). |
|||
Defective PF mainPWB. |
Replace the PF main PWB (Refer to the service manual for the paper feeder). |
|||
C0830 |
FAX control PWB flash program area checksum error |
A checksum error occurred with the program of the FAX control PWB. |
Defective fax software. |
Install the fax software. |
Defective FAX control PWB. |
Replace the FAX control PWB. |
|||
C0840 |
Faults of RTC |
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. |
Defective control PWB. |
Replace the control PWB. |
The battery is disconnected from the control PWB. |
Check visually and remedy if necessary. |
|||
C0870 |
FAX control PWB to control PWB high capacity data transfer problem |
High-capacity data transfer between the FAX control PWB and the control PWB of the machine was not normally performed even if the data transfer was retried the specified times. |
Improper installation FAX control PWB. |
Reinstall the FAX control PWB. |
Defective FAX control PWB or control PWB. |
Replace the FAX control PWB or control PWB and check for correct operation. |
|||
C0920 |
Fax file system error |
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. |
Defective FAX control PWB. |
Replace the FAX control PWB. |
C2000 |
Main motor error |
The main motor ready input is not given for 2 s during the main motor is ON. |
Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
Defective drive transmission system of the main motor. |
Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. |
|||
Defective main motor. |
Replace the main motor. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C2610 |
PF paper feed motor error (paper feeder) |
The PF paper feed motor of cassette 2 ready input is not given for 2 s during the PF paper feed motor is ON. |
Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). |
Defective PF paper feed motor drive transmission system. |
Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. |
|||
Defective PF main motor. |
Replace the PF main motor. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C2620 |
PF paper feed motor error (Paper feeder) |
The PF paper feed motor of cassette 3 ready input is not given for 2 s during the PF paper feed motor is ON. |
Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). |
Defective PF paper feed motor drive transmission system. |
Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. |
|||
Defective PF main motor. |
Replace the PF main motor (Refer to the service manual for the paper feeder). |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C3100 |
ISU home position error |
Defective FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit (ISU). |
|
Defective FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC insertion. |
Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. |
|||
Defective home position sensor. |
Replace the home position sensor. |
|||
Defective harness between ISU motor and scanner PWB (YC104), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
|||
Defective ISU motor. |
Replace the ISU motor. |
|||
C3200 |
Exposure lamp error |
The exposure lamp is not turned on. |
Defective FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC insertion. |
Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. |
Defective FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit (ISU) (See page 1-5-21). |
|||
Defective harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
|||
Defective harness between LED drive PWB (YC2) and exposure lamp, or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
|||
Defective exposure lamp. |
Replace the exposure lamp. |
|||
Defective LED drive PWB. |
Replace the LED drive PWB. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C3300 |
AGC error |
After AGC, correct input is not obtained at CCD. |
Defective FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit (ISU). |
Defective exposure lamp. |
Replace the exposure lamp. |
|||
Defective CCD PWB. |
Replace the CCD PWB. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C3500 |
CPU - ASIC (CCD PWB) communication error |
An error code is detected. |
Defective FFC between CCD PWB (YC1) and control PWB (YC8). |
Replace the image scanner unit (ISU). |
Defective CCD PWB. |
Replace the CCD PWB. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C4000 |
Polygon motor (laser scanner unit) error |
The polygon motor ready input is not given for 6 s during the polygon motor is ON. |
Defective harness between polygon motor and control PWB (YC10), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
Defective laser scanner unit. |
Replace the laser scanner unit. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C4200 |
BD error (laser scanner unit) error |
BD sensor does not detect laser beam due to condensation on the polygon mirror. |
Turn machine power off for at least 30 minutes, then turn machine on again. If not cured, replace the laser scanner unit. |
|
Defective laser scanner unit. |
Replace the laser scanner unit. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C6000 |
Broken Fuser heater wire |
The fuser temperature does not rise after the Fuser heater has been turned on. |
Poor contact in the fuser thermistor connector terminals. |
Reinsert the connector. |
Poor contact in the Fuser heater connector terminals. |
Reinsert the connector. |
|||
Fuser thermistor installed incorrectly. |
Replace the fuser unit. |
|||
Fuser thermal cutout triggered. |
Replace the fuser unit. |
|||
Fuser heater installed incorrectly. |
Replace the fuser unit. |
|||
Broken Fuser heater wire. |
Replace the fuser unit. |
|||
C6020 |
Abnormally high fuser thermistor temperature |
Fuser thermistor detects abnormally temperature. |
Shorted fuser thermistor. |
Replace the fuser unit. |
Defective control PWB. |
Replace the control PWB. |
|||
C6030 |
Broken fuser thermistor wire |
Input from fuser thermistor is 0 (A/D value). |
Poor contact in the fuser thermistor connector terminals. |
Reinsert the connector. |
Broken fuser thermistor wire. |
Replace the fuser unit. |
|||
Fuser thermistor installed incorrectly. |
Replace the fuser unit. |
|||
Fuser thermal cutout triggered. |
Replace the fuser unit. |
|||
Fuser heater installed incorrectly. |
Replace the fuser unit. |
|||
Broken Fuser heater wire. |
Replace the fuser unit. |
|||
C6400 |
Zero cross signal error |
The zero cross signal does not reach the control PWB for specified time. |
Defective harness between high voltage PWB (YC202) and control PWB (YC23), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (See page 1-5-37). |
Defective connection between power source PWB (YC103) and high voltage PWB (YC201). |
Reinsert the connector. |
|||
Defective power source PWB. |
Replace the power source PWB. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
C7990 |
Waste toner full |
The waste toner sensor has detected that the waste toner reservoir (drum unit) is full. |
Waste toner reservoir (drum unit) is full. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace the drum unit. |
Defective waste toner sensor. |
Replace the waste toner sensor. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
F000 |
Control PWB - Operation panel PWB communication error |
Defective harness between operation panel PWB (YC1) and control PWB (YC7), or improper connector insertion. |
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
|
Defective operation panel PWB. |
Replace the operation panel PWB. |
|||
Defective control PWB. |
Replace the control PWB. |
|||
F020 |
Control PWB RAM checksum error |
Defective main memory (RAM) on the control PWB. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |
|
Defective expanded memory (DIMM). |
Replace the expanded memory (DIMM). |
|||
F040 |
Control PWB engine communication error |
A communication error is detected. |
Defective control PWB. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |
F041 |
Control PWB - scanner PWB communication error |
A communication error is detected. |
Defective control PWB or scanner PWB. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB or scanner PWB. |
F050 |
Control PWB engine checksum error |
Some error may have occurred when downloading the firmware of the control PWB. |
Download the firmware of the control PWB again. |
|
Defective control PWB. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |
|||
F186 |
Control PWB video data control error |
Defective control PWB. |
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |