Оборудование оснащено функцией самодиагностики. При обнаружении проблемы, аппарат блокируется, на дисплее отображается код вида С#### с указанием характера проблемы. Также появляется сообщение необходимости обслуживания. После устранения проблемы, ошибку можно сбросить тумблером питания, выключив и включив аппарат.
| Код | Значение | Описание | Причина | Решение |
|---|---|---|---|---|
| C0030 | FAX control PWB system error | Processing with the fax software was disabled due to a hardware problem. | Defective FAX control PWB. | Replace the FAX control PWB. |
| C0070 | FAX control PWB incompatible detection Error | Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. | Defective fax software. | Install the fax software. |
| Defective FAX control PWB. | Replace the FAX control PWB. | |||
| C0100 | Backup memory device error | Defective flash memory. | Replace the control PWB. | |
| Defective control PWB. | Replace the control PWB. | |||
| C0120 | MAC address data error | Defective flash memory. | Replace the control PWB. | |
| C0130 | Backup memory read/write error | Defective flash memory. | Replace the control PWB. | |
| Defective control PWB. | Replace the control PWB. | |||
| C0140 | Backup memory data error | Defective flash memory. | Replace the control PWB. | |
| Defective control PWB. | Replace the control PWB. | |||
| C0150 | Control PWB EEPROM error | Detecting control PWB EEPROM (U17) communication error. | Improper installation control PWB EEPROM (U17). | Check the installation of the EEPROM (U17) and remedy if necessary. |
| Defective control PWB. | Replace the control PWB. | |||
| Data damage of control PWB EEPROM (U17). | Contact the Service Administrative Division. | |||
| C0170 | Billing counting error | Defective control PWB. | Replace the control PWB. | |
| Data damage of control PWB EEPROM (U17). | Contact the Service Administrative Division. | |||
| C0180 | Machine number mismatch | Machine number of main and engine does not match. | The main PWB or the engine PWB were exchanged. | U004 Setting the machine number. |
| Data damage of control PWB EEPROM (U17). | Contact the Service Administrative Division. | |||
| C0420 | Paper feeder communication error | Communication error between control PWB and optional paper feeder. | Improper installation paper feeder. | Follow installation instruction carefully again. |
| Defective harness between control PWB (YC30) and paper feeder interface connector, or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. | |||
| Defective control PWB. | Replace the control PWB. | |||
| Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). | |||
| Defective PF mainPWB. | Replace the PF main PWB (Refer to the service manual for the paper feeder). | |||
| C0830 | FAX control PWB flash program area checksum error | A checksum error occurred with the program of the FAX control PWB. | Defective fax software. | Install the fax software. |
| Defective FAX control PWB. | Replace the FAX control PWB. | |||
| C0840 | Faults of RTC | The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. | Defective control PWB. | Replace the control PWB. |
| The battery is disconnected from the control PWB. | Check visually and remedy if necessary. | |||
| C0870 | FAX control PWB to control PWB high capacity data transfer problem | High-capacity data transfer between the FAX control PWB and the control PWB of the machine was not normally performed even if the data transfer was retried the specified times. | Improper installation FAX control PWB. | Reinstall the FAX control PWB. |
| Defective FAX control PWB or control PWB. | Replace the FAX control PWB or control PWB and check for correct operation. | |||
| C0920 | Fax file system error | The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. | Defective FAX control PWB. | Replace the FAX control PWB. |
| C2000 | Main motor error | The main motor ready input is not given for 2 s during the main motor is ON. | Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
| Defective drive transmission system of the main motor. | Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. | |||
| Defective main motor. | Replace the main motor. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C2610 | PF paper feed motor error (paper feeder) | The PF paper feed motor of cassette 2 ready input is not given for 2 s during the PF paper feed motor is ON. | Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). |
| Defective PF paper feed motor drive transmission system. | Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. | |||
| Defective PF main motor. | Replace the PF main motor. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C2620 | PF paper feed motor error (Paper feeder) | The PF paper feed motor of cassette 3 ready input is not given for 2 s during the PF paper feed motor is ON. | Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). |
| Defective PF paper feed motor drive transmission system. | Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. | |||
| Defective PF main motor. | Replace the PF main motor (Refer to the service manual for the paper feeder). | |||
| Defective control PWB. | Replace the control PWB. | |||
| C3100 | ISU home position error | Defective FFC between CCD PWB (YC1) and control PWB (YC8). | Replace the image scanner unit (ISU). | |
| Defective FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC insertion. | Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. | |||
| Defective home position sensor. | Replace the home position sensor. | |||
| Defective harness between ISU motor and scanner PWB (YC104), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. | |||
| Defective ISU motor. | Replace the ISU motor. | |||
| C3200 | Exposure lamp error | The exposure lamp is not turned on. | Defective FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC insertion. | Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. |
| Defective FFC between CCD PWB (YC1) and control PWB (YC8). | Replace the image scanner unit (ISU) (See page 1-5-21). | |||
| Defective harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. | |||
| Defective harness between LED drive PWB (YC2) and exposure lamp, or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. | |||
| Defective exposure lamp. | Replace the exposure lamp. | |||
| Defective LED drive PWB. | Replace the LED drive PWB. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C3300 | AGC error | After AGC, correct input is not obtained at CCD. | Defective FFC between CCD PWB (YC1) and control PWB (YC8). | Replace the image scanner unit (ISU). |
| Defective exposure lamp. | Replace the exposure lamp. | |||
| Defective CCD PWB. | Replace the CCD PWB. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C3500 | CPU - ASIC (CCD PWB) communication error | An error code is detected. | Defective FFC between CCD PWB (YC1) and control PWB (YC8). | Replace the image scanner unit (ISU). |
| Defective CCD PWB. | Replace the CCD PWB. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C4000 | Polygon motor (laser scanner unit) error | The polygon motor ready input is not given for 6 s during the polygon motor is ON. | Defective harness between polygon motor and control PWB (YC10), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. |
| Defective laser scanner unit. | Replace the laser scanner unit. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C4200 | BD error (laser scanner unit) error | BD sensor does not detect laser beam due to condensation on the polygon mirror. | Turn machine power off for at least 30 minutes, then turn machine on again. If not cured, replace the laser scanner unit. | |
| Defective laser scanner unit. | Replace the laser scanner unit. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C6000 | Broken Fuser heater wire | The fuser temperature does not rise after the Fuser heater has been turned on. | Poor contact in the fuser thermistor connector terminals. | Reinsert the connector. |
| Poor contact in the Fuser heater connector terminals. | Reinsert the connector. | |||
| Fuser thermistor installed incorrectly. | Replace the fuser unit. | |||
| Fuser thermal cutout triggered. | Replace the fuser unit. | |||
| Fuser heater installed incorrectly. | Replace the fuser unit. | |||
| Broken Fuser heater wire. | Replace the fuser unit. | |||
| C6020 | Abnormally high fuser thermistor temperature | Fuser thermistor detects abnormally temperature. | Shorted fuser thermistor. | Replace the fuser unit. |
| Defective control PWB. | Replace the control PWB. | |||
| C6030 | Broken fuser thermistor wire | Input from fuser thermistor is 0 (A/D value). | Poor contact in the fuser thermistor connector terminals. | Reinsert the connector. |
| Broken fuser thermistor wire. | Replace the fuser unit. | |||
| Fuser thermistor installed incorrectly. | Replace the fuser unit. | |||
| Fuser thermal cutout triggered. | Replace the fuser unit. | |||
| Fuser heater installed incorrectly. | Replace the fuser unit. | |||
| Broken Fuser heater wire. | Replace the fuser unit. | |||
| C6400 | Zero cross signal error | The zero cross signal does not reach the control PWB for specified time. | Defective harness between high voltage PWB (YC202) and control PWB (YC23), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (See page 1-5-37). |
| Defective connection between power source PWB (YC103) and high voltage PWB (YC201). | Reinsert the connector. | |||
| Defective power source PWB. | Replace the power source PWB. | |||
| Defective control PWB. | Replace the control PWB. | |||
| C7990 | Waste toner full | The waste toner sensor has detected that the waste toner reservoir (drum unit) is full. | Waste toner reservoir (drum unit) is full. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace the drum unit. |
| Defective waste toner sensor. | Replace the waste toner sensor. | |||
| Defective control PWB. | Replace the control PWB. | |||
| F000 | Control PWB - Operation panel PWB communication error | Defective harness between operation panel PWB (YC1) and control PWB (YC7), or improper connector insertion. | Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. | |
| Defective operation panel PWB. | Replace the operation panel PWB. | |||
| Defective control PWB. | Replace the control PWB. | |||
| F020 | Control PWB RAM checksum error | Defective main memory (RAM) on the control PWB. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. | |
| Defective expanded memory (DIMM). | Replace the expanded memory (DIMM). | |||
| F040 | Control PWB engine communication error | A communication error is detected. | Defective control PWB. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |
| F041 | Control PWB - scanner PWB communication error | A communication error is detected. | Defective control PWB or scanner PWB. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB or scanner PWB. |
| F050 | Control PWB engine checksum error | Some error may have occurred when downloading the firmware of the control PWB. | Download the firmware of the control PWB again. | |
| Defective control PWB. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. | |||
| F186 | Control PWB video data control error | Defective control PWB. | Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. |